MATERIAL DATA SHEET

Coated steel sheet (Colorbond/Zincalume), various profiles (0.42mm, 0.48mm, 0.55mm, 0.60mm BMT)

Ferrous Sheet
mineral › Metallic › Ferrous Sheet
mineralmetallicaustralian-madebluescopecolorbondzincalumebal-ratedsustainablerecyclable
ATLAS CODE
MIN-MET-FSH-001
Coated steel sheet (Colorbond/Zincalume), various profiles (0.42mm, 0.48mm, 0.55mm, 0.60mm BMT)
Category mineral
Material Family Metallic
Regulatory Status Non-combustible per AS 1530.1
Density
7850 kg/m³
Carbon (A1-A5)
14.1 kg CO2-eq/m²
Fire Class
Non-combustible per AS 1530.1
Lifespan
50 – 100 years
Description

Colorbond and Zincalume are BlueScope's flagship coated steel products, featuring Activate® technology for enhanced corrosion resistance. Available in Base Metal Thickness (BMT) from 0.42mm to 0.60mm, with yield strengths of G300 (300 MPa) or G550 (550 MPa). Colorbond adds a five-layer paint system with Thermatech® solar reflectance technology, while Zincalume features the bare metallic coating for architectural applications.

Primary Sectors
[Residential][Commercial][Industrial]
Typical Uses
  • Residential roofing (all profiles)
  • Commercial/industrial roofing and walling
  • Architectural cladding systems
  • Rainwater goods (gutters, downpipes)
  • Fencing and screening
  • Garage doors and roller shutters
  • Insulated panel systems
  • Bushfire-rated construction (BAL-FZ)
  • Coastal and marine environments
  • Cold storage facilities
Recycled Content 25
Renewable Content 0
Recyclability 100
Embodied Carbon 14.1 kg CO2-eq/m²
Embodied Energy 148 MJ/m²
EPD Available Yes
Advantages
50+ year proven Australian performanceNon-combustible, BAL-FZ compliantLightweight (3.3-4.7 kg/m²)100% recyclable36-year warranty available22 standard colours plus specialty finishesThermatech® solar reflectance technologyActivate® corrosion resistance technologyTermite and rot proofLow thermal mass for improved comfort
Cautions
Higher initial cost than some alternativesCan dent under impactRequires compatible fasteners and flashingsThermal expansion requires proper detailingCut edges need protection in severe environmentsRegular washing required in sheltered areasCan be noisy in rain without insulation
TECHNICAL DATA: PERFORMANCE PROPERTIES MIN-MET-FSH-001
Density (Dry) 7850 kg/m³
Specific Gravity 7.85 dimensionless
Porosity 0 %
Water Absorption 0 %
Hardness 130 HV
Surface Roughness 1 μm Ra
UV Resistance Excellent
Chemical Resistance Good
pH Tolerance 4 – 9 pH
Compressive Strength 550 MPa
Tensile Strength 520 – 620 MPa
Flexural Strength 550 MPa
Shear Strength 330 MPa
Elastic Modulus 200000 MPa
Yield Strength 550 MPa
Impact Resistance Good J/m
Bearing Capacity 1.5 kN
Poisson's Ratio 0.3 dimensionless
Creep Resistance Excellent
Abrasion Resistance Very Good
Thermal Conductivity 45 W/m·K
Thermal Resistance 0.00001 m²·K/W
Specific Heat Capacity 460 J/kg·K
Thermal Expansion 11.7 ×10⁻⁶/°C
Melting Point 1500 °C
Ignition Temperature 500 °C
Sound Transmission Class (STC) 25 STC
Noise Reduction Coeff. (NRC) 0.05 dimensionless
Optical
Light Transmittance 0 %
Light Reflectance (LRV) 14 – 77 %
Solar Reflectance (SRI) 0 – 95 SRI

Zincalume introduced 1976, Colorbond 1966. Continuous development including Activate® technology (2013) and Thermatech® solar reflectance. Over 5,000 test panels in Australian exposure sites since 1960s. Industry standard for Australian metal roofing with billions of square metres installed.

SAFETY, ECOLOGY & INSTALLATION MIN-MET-FSH-001
Flame Spread Index 0 dimensionless
Smoke Developed Index 0 dimensionless
Combustibility Class Non-combustible per AS 1530.1
Ignition Temperature 500 °C
Fire Resistance Rating Non-combustible hours
Heat Release Rate 0 kW/m²
Toxicity of Combustion None - non-combustible material
Embodied Carbon (A1-A3) 14.1 kg CO2-eq/m²
Embodied Energy 148 MJ/m²
Water Footprint 40.7 L/m²
EPD Available Yes
Recycled Content 25%
Renewable Content 0%
LEED Points 2 – 4
Circular Economy Score 85 %
VOC Emissions 0 g/L
Skill Level Licensed tradesperson
Crew Size 2 – 4 persons
Installation Time 1 m²/person/hour
Curing Time 0 hours
Setting Time 0 hours
Temperature Range -10 – 50 °C
Humidity Range 0 – 100 %
Required Tools
Tin snips or electric shearsScrew guns with depth settingsString lines and levelsSafety equipment (harness, gloves)Sealants and compatible fasteners
Certifications Required
Roofing/cladding trade certificateWorking at heightsAsbestos awareness (for re-roofing)
Weather Limitations
No installation in electrical stormsAvoid high winds >60km/hEnsure dry conditions for sealants
COMMERCIAL, LOGISTICS & REGULATORY MIN-MET-FSH-001
Material Cost 18 – 40 $/m²
Installation Cost 65 – 100 $/m²
Annual Maintenance 0.5 $/m²/year
Lifecycle Cost (50yr) 2.5 $/m²/year
Market Availability Excellent - stocked nationally
Lead Time 1 – 14 days
Design Life 50 – 100 years
Maintenance Interval 6 months
Service Temp Range -40 – 200 °C
Freeze/Thaw Resistance Excellent - no degradation
Dimensional Stability 11.7 μm/m/°C
Certifications Held
ISO 9001 - Quality managementISO 14001 - Environmental managementResponsibleSteel certificationEPD to EN 15804Green Star compliantLEED v4 compliantREACH compliantNo hazardous substances
Fire Code Compliance
AS 3959:2018 - BAL-12.5 to BAL-FZAS 1530.1 - Non-combustibleAS 1530.3 - Indices of 0-0-0-0
Standards Compliance
NCC Volume One (Class 2-9)NCC Volume Two (Class 1 & 10)All state variationsISO 9223 - Corrosivity categoriesISO 12944 - Corrosion protectionISO 14713 - Zinc coatings

DISCLAIMER: This specification document is generated from the CLAD Materials Atlas Database. Information is for general guidance only and does not constitute professional engineering advice. Values are typical and may vary by batch, manufacturer, and production run. Verify suitability for specific project applications independently.

ID: MIN-MET-FSH-001 Schema: v3.0